Back to all articles
What does PAT testing involve for landlords?

What does PAT testing involve for landlords?

24 November 202611 min read

A PAT testing reminder for landlords works best as a simple appliance register. List every appliance you supply, record its last test date and result, and set a next-check date based on the appliance's type and use. Then add a calendar alert six to eight weeks ahead, so you have time to book and arrange tenant access.

Do landlords need PAT testing? The requirements in England

This checklist covers rented homes in England. Here is the legal position in brief before the practical side.

GOV.UK's guidance for private tenants says landlords must make sure that both the electrical system and any appliances they supply, such as cookers and kettles, are safe. For private landlords, that guidance does not name a specific test or set a fixed annual date for appliances. PAT is the usual way to show supplied items have been checked and that any problems were dealt with.

Social landlords are treated differently. The government's electrical safety standards guidance says social landlords must have the electrical equipment they supply checked at least every five years. That rule applies to the social sector. It is not a universal deadline for private lets.

The same guidance treats the fixed wiring inspection and its EICR as a separate job from appliance checks. An EICR does not cover the kettle, and a PAT visit does not cover the consumer unit.

Other UK nations: Scotland's Repairing Standard guidance includes in-service inspection and testing of landlord-provided appliances in the electrical safety inspection before a property is first let. Wales and Northern Ireland have their own housing law, so follow that nation's guidance for property there.

For the fuller background on responsibility and frequency, see our guide to who is responsible for PAT testing in rented properties and communal areas. The rest of this article covers the part that tends to slip: booking the visit, getting in and keeping records you can rely on.

How do landlords set up a PAT testing reminder?

A reminder is only as useful as the information behind it. A phone alert that just says "PAT – Flat 2" won't tell you what needs testing, who has the keys or what failed last time.

The Health and Safety Executive offers a sensible model: use diary reminders and review previous results to decide when equipment needs checking again, rather than automatically repeating every test on a fixed cycle.

In practice, keep an appliance register for each property. A spreadsheet is fine if it has:

  • Property address, including flat or unit number
  • Appliance (type, make, model and serial number if visible)
  • Location, for example "kitchen, integrated"
  • Date last tested and result
  • Next check due, with a one-line reason for that date
  • Who books it: you, your letting agent or a portfolio manager
  • Link to the last report

Set two alerts, not one

  1. A booking alert, six to eight weeks before the due date. Enough time to agree access, avoid holidays and fit around other visits.
  2. A follow-up alert, a week after the appointment. Confirm the report has arrived, the register is updated and any failed items have been dealt with.

The second alert is the one most often missing. The visit happens, the report sits unopened in an inbox and a failed toaster stays in the kitchen.

Put both alerts in a shared calendar if an agent or co-owner is involved, and set each property's PAT date next to its EPC and EICR dates so you can see where visits could be grouped. Our landlord compliance page sets out the services that can sit in the same plan.

A reminder timeline you can copy

| When | Task | Who usually handles it |
|---|---|---|
| 8 weeks before due | Booking alert fires; check the register is current | Landlord or agent |
| 6–8 weeks before | Book the visit; send the previous report to the tester | Landlord or agent |
| 2–4 weeks before | Written notice to tenant; ask about any faults | Agent or landlord |
| 1–2 days before | Confirm keys, parking and time window; send tenant a reminder | Agent or landlord |
| Visit day | Appliances inspected, tested and labelled | Tester |
| Within a week | Read the report; act on any failures | Landlord |
| After the visit | Update the register; set the next date and a new alert | Landlord or agent |

What information do I need to book PAT testing for a rental property?

Having the details ready makes booking quicker and means the tester arrives prepared. Gather:

  • Full address and postcode, flat number and any building entry codes
  • Property type and size, such as studio, two-bed flat or five-bed HMO
  • A rough count of landlord-supplied appliances. "About 8" and "about 30" mean very different visit lengths.
  • Whether the property is occupied or empty
  • Tenant contact details, or the agent's if they manage access
  • Key arrangements: key safe, agent collection or tenant at home
  • Parking notes, which matter in parts of central Slough and Maidenhead where on-street parking is tight
  • The previous PAT report, so appliances and labels can be matched
  • Preferred dates, including whether an evening or weekend slot suits the tenant better

AG Site Solutions' PAT testing starts from £65, with flexible appointments including evenings and weekends and online booking open 24/7. You can see what is included on our PAT testing service page or go straight to book a service.

Which landlord-supplied appliances should be included?

The working rule: if you supplied it and it plugs in, it goes on the list. Tenants' own appliances are their responsibility, and Scotland's guidance excludes them explicitly.

HSE's guidance on maintaining portable electric equipment defines portable equipment broadly. It includes the small items you would expect and large appliances that are rarely moved, such as fridges and washing machines. For a typical furnished or part-furnished let:

| Area | Typical landlord-supplied items |
|---|---|
| Kitchen | Fridge, freezer, washing machine, tumble dryer, dishwasher, microwave, kettle, toaster |
| Living areas | TV, lamps, portable heaters, fans |
| Cleaning | Vacuum cleaner |
| Leads and power | Extension leads, adaptors, mains chargers you supplied |

What catches landlords out:

  • Extension leads and adaptors count. A worn lead behind a sofa is exactly what an inspection is there to find.
  • Battery devices aren't the same as their chargers. HSE separates the two; the mains charger is the part to check.
  • Fixed items need agreeing. Hard-wired ovens or extractor fans may sit with the EICR rather than PAT. Scotland's guidance advises agreeing coverage so nothing falls between the two inspections, which is good practice in England too.
  • Unfurnished lets can still have appliances. A fridge-freezer left behind is landlord-supplied.

PAT testing and check-in reports do different jobs

A property inventory or check-in report records which appliances are in the property and how they look at the start of a tenancy. That is useful for deposits and for keeping your register accurate.

It is not an electrical safety test. An inventory clerk will note a cracked plug or missing cover, but doesn't test the appliance. Use the inventory as the starting list for PAT, not a replacement for it.

How do I arrange tenant access and prepare for the appointment?

Most access problems come from short notice or vague timings. Treat it like any planned visit:

  • Give written notice in line with your tenancy agreement and explain that the visit is a safety check on the appliances you supplied.
  • Offer a time window, such as "Tuesday, 9am to 12pm", not just a date.
  • Offer evenings or weekends for working tenants. It often saves a wasted trip.
  • Explain the disruption. Appliances are briefly unplugged, so the tenant should save anything important and expect short interruptions.
  • Ask for clear access to sockets behind the washing machine, fridge and TV unit.
  • Confirm keys if the tenant will be out, and get their consent to entry in advance.

In HMOs, contact each tenant or post a notice in shared areas. Appliances in individual rooms and communal kitchens both need covering.

Before the visit

  1. Update the register from the latest inventory, adding anything bought since.
  2. Replace anything already known to be broken rather than paying for it to fail.
  3. Send the previous report to the tester.
  4. Ask the tenant about faults. HSE lists user-reported faults as part of a formal inspection, so a quick "anything flickering, tripping or getting hot?" helps.
  5. Register appliances with manufacturers. Electrical Safety First recommends this for landlord-supplied appliances, so you hear about recalls.
  6. Decide who approves replacements, especially where an agent manages the visit, so a failed fridge isn't left unplugged for a week.

It helps to know what electrical PAT testing for landlords actually checks. HSE explains that PAT combines visual examination with appropriate electrical testing. The visual check finds many defects on its own, such as damaged cables or plugs, exposed wires, taped joints, scorching and loose parts; some faults only show up with test equipment. That is why the condition of everyday items like leads and plugs matters as much as the appliance itself.

If you already have other visits due, group them. Where suitable, AG Site Solutions can combine PAT testing with an EPC or a mid-term inspection during the same property visit, so the tenant gets one access request instead of two.

What happens if an appliance fails PAT testing?

HSE's guidance is direct: damaged or faulty equipment should be taken out of use without delay, then either repaired by a competent person or disposed of so nobody can use it again.

For a landlord, that becomes a short sequence:

  • Unplug the item and mark it not to be used; remove it if possible.
  • Tell the tenant in writing which item failed and what happens next.
  • Choose repair or replacement quickly. For kettles, toasters and extension leads, replacement is usually simpler.
  • Have a repaired item rechecked before it goes back into use.
  • Record the outcome: failed, date, and action taken.

HSE says new equipment should get a visual check for damage but doesn't generally need a formal PAT before first use. Add the replacement to your register so it is covered at the next visit.

Between tests, tenants are your early warning

A pass reflects the appliance's condition on the day, not until the next appointment. Electrical Safety First advises tenants to report electrical problems promptly and not to ignore burn marks, buzzing or crackling, repeated tripping or overheating.

Put a line about this in your move-in pack and make reporting easy. Our guide to an out-of-hours repair plan tenants can actually use shows how.

What PAT records should landlords keep, and when are appliances due again?

Records worth keeping

HSE notes that records and labels help you manage and review maintenance over time. For each property, keep:

  • Each PAT report, showing appliances tested, results and date
  • Your appliance register, updated after every visit, purchase or disposal
  • Evidence of action on failures: replacement receipts, repair invoices and retest results
  • Tenant fault reports and your response
  • Manufacturer registrations and any recall correspondence

Store it digitally, one folder per address. Portfolio managers with homes across Slough, Bracknell and High Wycombe will find that far easier than sorting by contractor.

Deciding the next check date

For private lets, HSE's position is that frequency depends on the type of equipment and the environment it's used in, and that intervals should be reviewed using fault history. (Social landlords in England work to the five-year maximum in the government guidance above.) The questions that shape a sensible date:

  • How hard is it used? A kettle in a busy HMO takes far more wear than a lamp in a one-person flat.
  • Is it moved around? Portable heaters and extension leads suffer more cable damage than an integrated fridge.
  • What did the last test find? Several failures mean a shorter interval. Repeated clean passes support keeping it.
  • Has the tenancy changed? A change of tenant is a natural recheck point, as you will already be visiting for check-out and check-in.
  • Are items grouped? HSE advises grouped equipment should follow the shortest interval that applies to any item. In practice, set one date per property based on its most demanding appliance.

Write the reason for each date in the register. When an agent, insurer or new manager asks why a property was tested when it was, the answer is already there.

When the reminder comes round, you can arrange the visit through our PAT testing for landlords service, or talk to our team on 020 3051 3973 for a free no-obligation quote.

Related articles